Voltage clamp - Wikipedia, the free encyclopedia. The voltage clamp operates by negative feedback. The membrane potential amplifier measures membrane voltage and sends output to the feedback amplifier; this subtracts the membrane voltage from the command voltage, which it receives from the signal generator. The patch-clamp technique allows the investigation of a small set or even single ion channels. The most commonly used patch-clamp mode is the whole-cell mode (Figure 3). To achieve this mode. Patch-Clamp Analysis ADVANCED TECHNIQUES Second Edition Edited by Wolfgang Walz. La eficiencia de esta t. El “whole-cell patch” permite acceso al interior de la c The technique of patch-clamp recording in brain slices is applicable to a large variety of cell types in slices from nearly all areas of the central nervous system (CNS) in. Patch clamp - 1 La tecnica del voltage clampci ha permesso di studiare le correnti ioniche transmembranarie. Axon Conventional Patch Clamp. Axopatch 200B; MultiClamp 700B; Axoclamp 900A; Digidata 1550B. HumSilencer Technology; pCLAMP 10 Software; Axoporator 800A. Two-electrode voltage-clamp and whole-cell current-clamp recordings. Estudio de la fisiolog. Automated whole-cell patch clamp electrophysiology of neurons in vivo - Duration: 4:58. Craig Forest 33,435 views. Il comportamento dei singoli canali . La condizione di ”whole cell. Whole cell Para llevar a cabo. Electricidad ganglio trig This signal is amplified and output is sent into the axon via the current electrode. The voltage clamp is an experimental method used by electrophysiologists to measure the ioncurrents through the membranes of excitable cells, such as neurons, while holding the membrane voltage at a set level. A basic voltage clamp will iteratively measure the membrane potential, and then change the membrane potential (voltage) to a desired value by adding the necessary current. Because the currents applied to the cell must be equal to (and opposite in charge to) the current going across the cell membrane at the set voltage, the recorded currents indicate how the cell reacts to changes in membrane potential. The voltage clamp allows the membrane voltage to be manipulated independently of the ionic currents, allowing the current- voltage relationships of membrane channels to be studied. Cole discovered that it was possible to use two electrodes and a feedback circuit to keep the cell'smembrane potential at a level set by the experimenter. Cole developed the voltage clamp technique before the era of microelectrodes, so his two electrodes consisted of fine wires twisted around an insulating rod. Because this type of electrode could be inserted into only the largest cells, early electrophysiological experiments were conducted almost exclusively on squid axons. Walter Woodbury. Squids squirt jets of water when they need to move quickly, as when escaping a predator. To make this escape as fast as possible, they have an axon that can reach 1 mm in diameter (signals propagate more quickly down large axons). The squid giant axon was the first preparation that could be used to voltage clamp a transmembrane current, and it was the basis of Hodgkin and Huxley's pioneering experiments on the properties of the action potential. The use of voltage clamps in their experiments to study and model the action potential in detail has laid the foundation for electrophysiology; for which they shared the 1. Nobel Prize in Physiology or Medicine. Transmembrane voltage is recorded through a . The experimenter sets a . The electrodes are connected to an amplifier, which measures membrane potential and feeds the signal into a feedback amplifier. This amplifier also gets an input from the signal generator that determines the command potential, and it subtracts the membrane potential from the command potential (Vcommand . Whenever the cell deviates from the holding voltage, the operational amplifier generates an . The feedback circuit passes current into the cell to reduce the error signal to zero. Thus, the clamp circuit produces a current equal and opposite to the ionic current. Variations of the voltage clamp technique. The large size of these oocytes allows for easy handling and manipulability. By taking a reading of the changes in ion current, scientists can determine how cells are affected by a neurotransmitter, antibiotic, etc. This provides clues about the mechanisms of certain proteins or channels. The TEVC method utilizes two low- resistance pipettes, one sensing voltage and the other injecting current. The microelectrodes are filled with conductive solution and inserted into the cell to artificially control membrane potential. The membrane acts as a dielectric as well as a resistor, while the fluids on either side of the membrane function as capacitors. Current readings can be used to analyze the electrical response of the cell to different applications. This technique is favored over single- microelectrode clamp or other voltage clamp techniques when conditions call for resolving large currents. The high current- passing capacity of the two- electrode clamp makes it possible to clamp large currents that are impossible to control with single- electrode patch techniques. However, TEVC is limited in use with regard to cell size. It is effective in larger- diameter oocytes, but more difficult to use with small cells. Additionally, TEVC method is limited in that the transmitter of current must be contained in the pipette. It is not possible to manipulate the intracellular fluid while clamping, which is possible using patch clamp techniques. Cole's voltage clamp used a long wire that clamped the squid axon uniformly along its entire length. TEVC microelectrodes can provide only a spatial point source of current that may not uniformly affect all parts of an irregularly shaped cell. Dual- cell voltage clamp. When two cells in which gap junction proteins are expressed either endogenously or via injection of m. RNA, a junction channel will form between the cells. Since two cells are present in the system, two sets of electrodes are used. A recording electrode and a current injecting electrode are inserted into each cell, and each cell is clamped individually (each set of electrodes is attached to a separate apparatus, and integration of data is performed by computer). To record junctional conductance, the current is varied in the first cell while the recording electrode in the second cell records any changes in Vm for the second cell only. This single electrode carries out the functions of both current injection and recording. Continuous single- electrode clamp (SEV- c). It uses an electrode with a relatively large tip (> 1 micrometer) that has a smooth surface (rather than a sharp tip). This electrode is pressed against a cell membrane and suction is applied to pull the cell's membrane inside the electrode tip. The suction causes the cell to form a tight seal with the electrode (a . However: Microelectrodes are imperfect conductors; in general, they have a resistance of more than a million ohms. They rectify (i. e., change their resistance with voltage, often in an irregular manner), they sometimes have unstable resistance if clogged by cell contents. Thus, they will not faithfully record the voltage of the cell, especially when it is changing quickly, nor will they faithfully pass current. Voltage and current errors: SEV- c circuitry does not actually measure the voltage of the cell being clamped (as does a two- electrode clamp). The patch- clamp amplifier is like a two- electrode clamp, except the voltage measuring and current passing circuits are connected (in the two- electrode clamp, they are connected through the cell). The electrode is attached to a wire that contacts the current/voltage loop inside the amplifier. Thus, the electrode has only an indirect influence on the feedback circuit. The amplifier reads only the voltage at the top of the electrode, and feeds back current to compensate. But, if the electrode is an imperfect conductor, the clamp circuity has only a distorted view of the membrane potential. Likewise, when the circuit passes back current to compensate for that (distorted) voltage, the current will be distorted by the electrode before it reaches the cell. To compensate for this, the electrophysiologist uses the lowest resistance electrode possible, makes sure that the electrode characteristics do not change during an experiment (so the errors will be constant), and avoids recording currents with kinetics likely to be too fast for the clamp to follow accurately. The accuracy of SEV- c goes up the slower and smaller are the voltage changes it is trying to clamp. Series resistance errors: The currents passed to the cell must go to ground to complete the circuit. The voltages are recorded by the amplifier relative to ground. When a cell is clamped at its natural resting potential, there is no problem; the clamp is not passing current and the voltage is being generated only by the cell. But, when clamping at a different potential, series resistance errors become a concern; the cell will pass current across its membrane in an attempt to return to its natural resting potential. The clamp amplifier opposes this by passing current to maintain the holding potential. A problem arises because the electrode is between the amplifier and the cell; i. Thus, when passing current through the electrode and the cell, Ohm's Law tells us that this will cause a voltage to form across both the cell's and the electrode's resistance. As these resistors are in series, the voltage drops will add. If the electrode and the cell membrane have equal resistances (which they usually do not), and if the experimenter command a 4. V change from the resting potential, the amplifier will pass enough current until it reads that it has achieved that 4. V change. However, in this example, half of that voltage drop is across the electrode. The experimenter thinks he or she has moved the cell voltage by 4. V, but has moved it only by 2. V. The difference is the . Modern patch- clamp amplifiers have circuity to compensate for this error, but these compensate only 7. The electrophysiologist can further reduce the error by recording at or near the cell's natural resting potential, and by using as low a resistance electrode as possible. Capacitance errors. Microelectrodes are capacitors, and are particularly troublesome because they are non- linear. The capacitance arises because the electrolyte inside the electrode is separated by an insulator (glass) from the solution outside. This is, by definition and function, a capacitor. Worse, as the thickness of the glass changes the farther you get from the tip, the time constant of the capacitor will vary. This produces a distorted record of membrane voltage or current whenever they are changing. Amplifiers can compensate for this, but not entirely because the capacitance has many time- constants.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
December 2016
Categories |